top of page

     Air to Water Heat Pump Technical

bosch.png
Pack Shot (3)_edited.png

Technical facts: 

Operating the air / water

Max Heat output 7/35 1)~ 5 kW~ 7 kW~ 9 kW~ 13 kW~ 17 kW

Heat output (+7 / 35) 2)2.03 kW2.96 kW3.13 kW4.99 kW4.90 kW

COP (+7 / 35) 2)4.574.845.094.904.99

Heat output (-7/35) 3)4.57 kW6.18 kW7.61 kW10.60 kW12,45 kW

COP (-7/35) 3)2.892.822.642.682.55

Fan

Airflow4500 m³ / h7300 m³ / h

Fan speedsModulating

Compressor

TypeInverter Rotary

Weight refrigerant R410A1.70 kg1.75 kg2.35 kg3.30 kg4.0 kg

DefrostingActive

Values ​​for electrical connection

Wiring230V 1N ~400V 3N ~

Total power / Fuse2.3 KW/10 A3.2 kW/16 A3.6 kW/16 A7.2 kW/13 A

Degree of protectionIP X4

Generally

Sound effect 4)53 dB (A)

Sound pressure 1m 4)40 dB (A)

Dimensions (width x depth x height)930x440x1370 mm1200x580x1680 mm

Weight (without packaging)67 kg71 kg75 kg130 kg132 kg

1) ACCORDING TO EN 14511 2) ENLINGT EN 14511 (40% COMPRESSOR CAPACITY) 3) ACCORDING TO EN 14511 (100% COMPRESSOR POWER) 4) UNDER 12102 (AT NOMINAL OPERATING 40%)

 

Technical facts: AirBox

ModelE9E15S 50-90S 130-170E9 50-90E9 130-170

Heater

Nominal flow1305 l / h2151 l / h932 L / h1537 l / h1305 l / h2151 l / h

Max. supply temperature60 ° C

Max. permissible operating pressure3 bar

Connection25 mm

Hot water

Volume water heater185 l-

PreparerStainless-

Values ​​for electrical connection

Wiring400V 3N ~230V 1N ~400V 3N ~

Total power / Fuse9.5 kW/16 A15.2 kW/25 A1.5 kW/10 A9.5 kW/16 A

Output Stage / Electric Boiler 1)1.5 / 2/3/4, 5/6/9/15 kW (15 kW = E15)

Degree of protectionIP X1

Generally

ControllerRego 2000

Dimensions (width x depth x height)600x645x1800 mm485x386x700 mm

Weight (without packaging)135 kg28 kg30 kg

1) YOU CAN LIMIT THE IMMERSION HEATER FOR OPTIMAL BBR-ADAPTATION

bottom of page